Secondary Type URD Cable

Cables by Type

Secondary Type URD Cable

Secondary Type URD Cable is commonly used in applications requiring one, two, three, or four electrical pathways. These conductors serve as the primary routes for transmitting electrical power in distribution systems, running side by side throughout the length of the cable. Our comprehensive range of wires and cables ensures reliability, safety, and compliance with international standards.

Our URD cables are engineered with high conductivity to ensure efficient power transmission. They are well-insulated to provide electrical insulation and protection from environmental factors. Additionally, some cables feature an outer jacket for added mechanical protection and resistance to moisture and abrasion. Available in various sizes and types, they suit different applications. Each product complies with international standards for safety and performance.

Applications

● Individual Service Lines: Providing dedicated power lines from distribution transformers to individual residential or commercial buildings.
● Secondary Distribution Lines: Connecting secondary distribution transformers to primary distribution lines.
● Temporary Installations: Utilized as temporary power lines during construction projects or emergency situations.
● Dual Service Lines: Providing two separate power lines from distribution transformers to individual residential or commercial buildings.
● Multiple Service Lines: Providing three separate power lines from distribution transformers to individual residential or commercial buildings, allowing for distinct power circuits.

Secondary Type URD Cables Construction

Secondary Type URD Cables are constructed with the following key components:
Conductor: Typically made from high-quality copper or aluminum, providing excellent electrical conductivity and mechanical strength.
Insulation: Materials such as PE (polyethylene) and XLPE (cross-linked polyethylene) are used to insulate the conductors, ensuring electrical safety and durability.
Sheathing: Additional protective layers, such as PVC (polyvinyl chloride) or PE (polyethylene), are applied to some cables to provide mechanical protection and enhanced safety in case of fire.

Product Table

Conductor Voltage Rating (V) Conductor Material Insulation Material Sheathing Material
Single 600 Copper/Aluminium XLPE/PE PVC/PE
Duplex 600 Copper/Aluminium XLPE/PE PVC/PE
Triplex 600 Copper/Aluminium XLPE/PE PVC/PE
Quadruplex 600 Copper/Aluminium XLPE/PE PVC/PE

Standard

ASTM B-230

1. Title: Standard Specification for Aluminum 1350-H19 Wire for Electrical Purposes.
2. Scope: This specification covers aluminum 1350-H19 (extra hard) round wire for electrical purposes.

ASTM B-231

1. Title: Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors.
2. Scope: This specification covers aluminum 1350-H19 (extra hard), 1350-H16 or -H26 (3/4 hard), 1350-H14 or -H24 (1/2 hard), and 1350-H142 or -H242 (1/2 hard), bare concentric-lay-stranded conductors constructed with a straight round central wire surrounded by one or more layers of helically laid wires. The conductors are for general use for electrical purposes.

ASTM B-786

1. Title: Standard Specification for 19 Wire Combination Unilay-Stranded Aluminum Conductors for Subsequent Insulation.
2. Scope: This specification covers bare combination unilay-stranded conductors made from round wires of aluminum 1350 and 8000 series of aluminum alloys, for insulated conductors for electrical purposes. Aluminum 1350 wires in tempers -H19 (extra hard), -H16 or -H26 (3/4 hard), -H14 or -H24 (1/2 hard), and -H142 or -H242 (1/2 hard) and 8000 series aluminum alloys wires in tempers "O" and H1X or H2X are permitted. These conductors shall be constructed with a central core wire surrounded by two layers of helically laid wires, resulting in an outer diameter equal to the compressed-stranded equivalent conductors.

ASTM B-901

1. Title: Standard Specification for Compressed Round Stranded Aluminum Conductors Using Single Input Wire Construction.
2. Scope: This specification covers aluminum 1350-H19 (extra hard), 1350-H16 or -H26 (3/4 hard), 1350-H14 or -H24 (1/2 hard), 1350-H142 or -H242 (1/2 hard), and aluminum alloy 8000 series as listed in Specification B800 for tempers "O" and H1X or H2X, bare stranded conductors composed of one or more roller-shaped or die-compressed layers of helically laid wires. The conductors are for general use for electrical purposes.

ICEA S-105-692

1. Title: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables
2. Scope: This standard applies to the materials, constructions, and testing of single conductor cables and assemblies of completed single conductor thermoset insulated cables, with an insulated or bare copper or an insulated aluminum neutral, used for the distribution of electrical energy at phase-to-phase voltages not exceeding 600 volts, or phase-to-ground voltage not exceeding 480 volts, 60 Hz, and at conductor temperatures not exceeding 90°C for use in direct burial and underground ducts.